Number of Threshold Levels
Number of Threshold Levels
The threshold interval specified by [T Lower threshold] and [U Upper
threshold] is broken into the number of steps specified by this field.
Particles with an intensity above the midpoint of this field are treated
as "normal" intensity, while those below are considered "faint".
Note that
the tracking process will not use threshold steps smaller than four
intensity units, even if such steps are implied by the value for this
field.
Number of threshold levels ?
This entry specifies the number of different thresholds particles will be
searched for in the specified range. The smaller the number of thresholds
the faster the particles will be located. The larger the number of
thresholds, the better DigImage will be able to discriminate between two
particles very close together. The minimum number of thresholds is two.
The maximum number is determined by the the tracking process which will
not use threshold steps smaller than four intensity units, even if such
steps are implied by the value for this field.